产品详情
产品概述(Product Details)
ClinMax™ Human CXCL10/IP-10 ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human CXCL10/IP10 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ClinMax™ ELISA Kit provides several benefits:
- Standards to calibrate with NIBSC/WHO standards for comparable results.
- Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
- High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
- Simplified and straightforward protocols and ready-to-use reagents to save assay time.
应用说明(Application)
The kit is developed for quantitative detection of natural and recombinant human CXCL10/IP10 in serum, plasma and cell culture supernatants.
It is for research use only.
流程图(Workflow)
关键信息(Key Features)
Assay TypeSandwich-ELISAAnalyteCXCL10/IP-10Format96-wells plate breakable into 12 x 8 wells stripsReactivityHumanSensitivity<31.25pg/mLAssay Time2 hr 45 minSample volume50 uLRange31.25 pg/mL-2000 pg/mLSample TypeCell Culture Supernatants, Plasma, Serum.Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.
存储(Storage)
Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.
组分(Materials Provided)
IDComponentsSizeCEA028-C01Pre-coated Anti-IP-10 Antibody Microplate1 plateCEA028-C02Human IP-10 Standard163 ug×2CEA028-C03Biotin-Anti-IP-10 Antibody Con. Solution100 μLCEA028-C04Biotin-Antibody Dilution Buffer8 mLCEA028-C05Streptavidin-HRP Con. Solution500 μLCEA028-C06Streptavidin-HRP Dilution Buffer15 mLCEA028-C0720× Washing Buffer50 mLCEA028-C08Sample Dilution Buffer15 mL×2CEA028-C09Substrate Solution12 mLCEA028-C10Stop Solution6 mL质量管理控制体系(QMS)
产品展示
典型数据-Typical Data
Please refer to DS document for the assay protocol.
For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of CXCL10/IP-10 is less than 31.25 pg/mL.
批内差异(Intra-Assay Statistics)
Ten replicates of each of 4 samples containing different CXCL10/IP-10 concentrations were tested in one assay. Acceptable criteria: CV<10%.
批间差异(Inter-Assay Statistics)
Five samples containing different concentrations of CXCL10/IP-10 were tested in independent assays. Acceptable criteria: CV<15%.
回收率(Recovery)
Recombinant CXCL10/IP-10 was spiked into 3 human serum samples, and then analyzed. The average recovery of CXCL10/IP-10 for serum samples is 101.5%.